First, the determination of soil moisture recorder
The standard count of the soil moisture recorder is a reference frame for calculating the count ratio, and its accuracy has a great influence on the accuracy of the final measurement result. In general, it is not necessary to consider the effect of radioactive decay on the standard count. However, the standard count has a certain relationship with the temperature. Therefore, when used in an environment with large temperature difference, the soil moisture recorder needs to be calibrated, and the corresponding standard count is set according to the use environment. In addition, the standard count of the instrument is greatly affected by the environment in which the instrument is placed, so it should always be performed in the same environment when counting the standard. The calibration requires no foreign matter to exist within 2m of the instrument.
Second, to prevent the interference of condensate in the soil moisture recorder
Condensate in the instrument tube is caused by changes in temperature. When used, it is often found that there are water droplets on the inner wall of the tube, especially in the morning. The interference with the measurement results in the presence of condensed water is very large. Therefore, it is necessary to check before the measurement, and it is found that this situation should be processed in time to ensure the accuracy and reliability of the measurement results.
Third, do a good job of protection
If the work is carried out in full accordance with the operating regulations, the radiation damage of the soil moisture temperature measuring instrument to the human body can be ignored. But there are a few things to pay special attention to. First, the probe must never be placed outside the instrument in an unmeasured state (the soil moisture recorder is placed on the catheter at the end). Second, the protective part of the lower part of the instrument should not be opened or replaced. Third, the soil moisture recorder should be banned from the last trained personnel. The instrument should also be kept in a safe place to prevent children from approaching and playing.
Male Pin Headers & Min Jumper Series
Mini Jumper:The short-circuit cap is a 1.27mm,2.00mm, 2.54mm 5.08mm circuit sheet metal. As long as it is 2 pins, the short-circuit cap can be used to short it.
What is the function of the short circuit cap? Short circuit cap, I call it short circuit block. For example, if you use a single row of pins, you can use the short circuit block to short circuit the two adjacent pins (that is, to realize the connection on the circuit). For example, if you have a three wire pin, you can use a short circuit block to realize the function of dial switch.
Mini Jumper
ShenZhen Antenk Electronics Co,Ltd , https://www.antenksocket.com