Model NO.: QUW-05
Detection mode: Direct Reflection Type
IP Rating: IP67
Certification: ISO
Customized: Customized
Types: Non Contact
Power Supply: 12/24VDC
Beam Angle: 15°,12°,9°
Detection Accuracy: 0.25 ~ 0.5% Fs
Blind Area: ≤ 100 ~ 800mm (According to Different Range)
Trademark: QYE
Transport Package: Inner Side Plastic Bags, Outside Carton Box
Specification: CE, Rohs, Ex, ISO9001.2000
Origin: Shaanxi, China
HS Code: 90262090
Ultrasonic level sensor / for liquids / for tanks / non-contact 4-20mA / 0-5V / 0-10V
Features:1. Non contact
2. Easy to installation
3. Small in size, light in weight
4. 12/24VDC Power supply
5. Long working life and high reliability.
Dimensions:
-
Connecting Method:
-

Â
- Technical Specifications:
Part number |
QUW-05 |
Sensing range sd |
500Â ~ 8000 mm
|
Adjustment |
Yes |
Sonic frequency |
65Â KHz
|
Response time |
30 ms |
Voltage supply range +Vs |
15~30 VDC
|
Current consumption max. |
35 mA |
Output signal |
4~20ma |
Adjustment |
Yes |
LED Â yellow |
solid yellow: object in the evaluation range yellow  flashing: program function, object detected
|
LED Â red |
solid red: Error red  flashing: program function, object not detected
|
Type |
Cylindrical |
Housing material |
nickel-plated |
Width / diameter |
30Â mm
|
Height / length |
112Â mm
|
Connection types |
Connector M12 |
Operating temperature |
-25~ +70 °C |
Storage temperature |
-40~+80°C |
Protection class |
IP 68
|
Programmed Analogue Output Function:

A1:Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â
unusable areaA2: Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â
nominal sensing rangeMode of operation: Â
rising rampÂ
Adjusting The Evaluation Limits The ultrasonic sensor features an analogue output with two teachable evaluation limits. These are set by applying the supplyÂ
voltage -U or +U to the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1s. LEDsÂ
indicate whether the sensor has recognized the target during the TEACH-IN procedure. The lower evaluation limit A1 is taughtÂ
with -U, A2 with +U.Â
TEACH-IN rising ramp (A2 > A1)- Position object at lower evaluation limit- TEACH-IN lower limit A1 with - U- Position object at upper evaluation limit- TEACH-IN upper limit A2 with + UÂ
TEACH-IN falling ramp (A1 > A2):- Position object at lower evaluation limit- TEACH-IN lower limit A2 with + U- Position object at upper evaluation limit- TEACH-IN upper limit A1 with - UÂ
LED DisplaysÂ
Displays in dependence on operating mode |
Red LED |
Yellow LED |
Teach-In evaluation limit
|
 |
 |
Object detected |
Off
|
Flash |
No object detected |
Flash |
Off
|
Object uncertain (Teach-In invalid)
|
On
|
Off
|
Normal mode (evaluation range) |
Off
|
On
|
Fault |
On
|
Previous state
|



Please contact us to make an order now !
LED Street Light