Model | ESSW10GCQ | ESSW15GCQ | ESSW20GCQ | ESSW25GCQ | ESSW40GCQ | ||
Technical Parameter | |||||||
Heating input power | Hot water | KW | 2.13 | 2.39 | 4.25 | 5.08 | 8.5 |
Heating capacity | KW | 10.4 | 11.6 | 20.8 | 24.7 | 41.6 | |
Max outlet water temp | ºC | 60 | 60 | 60 | 60 | 60 | |
COP | Â | 4.88Â | 4.85Â | 4.89Â | 4.86Â | 4.89Â | |
Cooling input power | Cooling | KW | 1.5 | 1.7 | 3 | 3.4 | 6 |
Cooling capacity | KW | 6.8 | 7.8 | 14 | 16.5 | 28 | |
Min outlet water temp | ºC | 8 | 8 | 8 | 8 | 8 | |
EER | Â | 4.53Â | 4.59Â | 4.67Â | 4.85Â | 4.67Â | |
Input power | Heating | KW | 2.1 | 2.35 | 4.15 | 4.9 | 8.35 |
Heating capacity | KW | 10.5 | 11.8 | 21.3 | 25.2 | 42.6 | |
Max outlet water temp | ºC | 55 | 55 | 55 | 55 | 55 | |
COP | Â | 5.00Â | 5.02Â | 5.13Â | 5.14Â | 5.10Â | |
Pipe size | mm | 25 | 25 | 25 | 25 | 32 | |
Unit noise | db | 50 | 50 | 50 | 50 | 50 | |
N.W. | kg | 100 | 100 | 122 | 129.5 | 229.5 | |
G.W. | kg | 132 | 132 | 154 | 161.5 | 279.5 | |
Level of protection |  | IPX4 | IPX4 | IPX4 | IPX4 | IPX4 | |
Electric shock proof grade |  | I | I | I | I | I | |
Unit Standard Components | |||||||
Unit cabinet |  | Galvanized sheet/ Spray coating / gray color | |||||
Unit dimension | mm | 740*550*1000 | 740*550*1000 | 740*550*1000 | 740*550*1000 | 1000*600*1400 | |
Packing dimension | mm | 820*650*1150 | 820*650*1150 | 820*650*1150 | 820*650*1150 | 1090*705*1560 | |
Refrigerant | Â | R407C/2.4kg*1 | R407C/2.4kg*1 | R407C/3.3kg*1 | R407C/3.6kg*1 | R407C/3.3kg*2 | |
Power supply |  | 220V~240V/50Hz | 380V~415V/50Hz/3ph | ||||
Unit compressor |  | Copeland. | |||||
Hot water side heat exchanger |  | Shell and tube | |||||
A/C side heat exchanger |  | Plate Type | |||||
source side heat exchanger |  | Plate Type | |||||
4-way valve |  | SANHUA | |||||
Thermal expansion valve |  | Emerson | |||||
AC contactor and thermal relay |  | Fuji | |||||
Controller |  | Eurostars multiple function controller | |||||
Protection function |  | Temperature protection, time protection, water flow protection, antifreeze protection, current protection | |||||
Water pressure switch |  | 0.015Mpa :OFF,  0.03Mpa: ON | |||||
High pressure switch |  | 3.0/3.4MPa | |||||
Low pressure switch |  | 0.15/0.32MPa | |||||
Unit working mode |  | Heating mode, Cooling mode, Hot water mode, Heating + Hot water mode, Cooling + Hot water mode |
Geothermal Source Heat Pump(Heating-Cooling-Hot Water) | |||||||
Model | ESSW50GCQ | ESSW55GCQ | ESSW75GCQ | ESSW95GCQ | Â | ||
Technical Parameter | |||||||
Heating input power | Hot water | KW | 10.16 | 11.4 | 15.1 | 20.2 |  |
Heating capacity | KW | 49.4 | 55.4 | 73.1 | 97.2 |  | |
Max outlet water temp | ºC | 60 | 60 | 60 | 60 |  | |
COP | Â | 4.86Â | 4.86Â | 4.84Â | 4.81Â | Â | |
Cooling input power | Cooling | KW | 6.8 | 7.7 | 9.9 | 13.2 |  |
Cooling capacity | KW | 33 | 37.1 | 49.4 | 67 |  | |
Min outlet water temp | ºC | 8 | 8 | 8 | 8 |  | |
EER | Â | 4.85Â | 4.82Â | 4.99Â | 5.08Â | Â | |
Input power | Heating | KW | 9.84 | 10.8 | 14.5 | 19.5 |  |
Heating capacity | KW | 50.4 | 56.7 | 74.8 | 99.4 |  | |
Max outlet water temp | ºC | 55 | 55 | 55 | 55 |  | |
COP | Â | 5.12Â | 5.25Â | 5.16Â | 5.10Â | Â | |
Pipe size | mm | 32 | 32 | 50 | 65 |  | |
Unit noise | db | 55 | 55 | 55 | 55 |  | |
N.W. | kg | 244.5 | 428.5 | 566 | 614.5 | Â | |
G.W. | kg | 294.5 | 498.5 | 656 | 714.5 | Â | |
Level of protection |  | IPX4 | IPX4 | IPX4 | IPX4 |  | |
Electric shock proof grade |  | I | I | I | I |  | |
Unit Standard Components | |||||||
Unit cabinet |  | Galvanized sheet/ Spray coating / gray color | |||||
Unit dimension | mm | 1000*600*1400 | 1320*840*1130 | 1750*1120*1160 | 2000*1120*1160 |  | |
Packing dimension | mm | 1090*705*1560 | 1410*940*1290 | 1850*1225*1340 | 2100*1225*1340 |  | |
Refrigerant | Â | R407C/3.6kg*2 | R407C/5kg*2 | R407C/7kg*2 | R407C/9kg*2 | Â | |
Power supply |  | 380V~415V/50Hz/3ph | |||||
Unit compressor |  | Copeland. | |||||
Hot water side heat exchanger |  | Shell and tube |  | ||||
A/C side heat exchanger |  | Plate Type | |||||
source side heat exchanger |  | Plate Type | |||||
4-way valve |  | SANHUA | |||||
Thermal expansion valve |  | Emerson | |||||
AC contactor and thermal relay |  | Fuji | |||||
Controller |  | Eurostars multiple function controller | |||||
Protection function |  | Temperature protection, time protection, water flow protection, antifreeze protection, current protection | |||||
Water pressure switch |  | 0.015Mpa :OFF,  0.03Mpa: ON | |||||
High pressure switch |  | 3.0/3.4MPa | |||||
Low pressure switch |  | 0.15/0.32MPa | |||||
Unit working mode |  | Heating mode, Cooling mode, Hot water mode, Heating + Hot water mode, Cooling + Hot water mode |
Swing Steel Electro-hydraulic Actuator
Swing Steel Electro-hydraulic Actuator When we need abnormal anti deviation ability, high thrust and fast formation speed, we often choose hydraulic or electro-hydraulic actuator. Because of the incompressibility of the liquid, the advantage of using the hydraulic actuator is the better anti deviation ability, which is very important for the regulating working condition, because when the regulating element is close to the valve seat, the flow working condition is unstable, and the greater the pressure difference, the worse this situation is. In addition, the hydraulic actuator runs very smoothly and responds quickly, so it can realize high-precision control.
Swing Steel Electro-Hydraulic Actuator,Hydraulic Actuator For Industrial,Electro-Hydraulic Actuator,Hydraulic Actuator Electro
Taizhou Jiabo Instrument Technology Co., Ltd. , https://www.jbcbyq.com