100V, 250mA, surface mount, high speed switching diode
![]()
DFN1006 TP-RCLAMP3321P ESD Diode Low Capacitance
After having breakfast and my family is playing cards, my son came to report the TV strike, and I couldn’t open it. This depressed
I was still complacent, thinking that I could pass a year of cessation this year (13 years of the 30th year, the truck broke the wire rod and broke the net, 14 years of the lunar 28 roadside shops broke the fire and broke the cable). Calling a friend who repaired TV, answering at his hometown, coming back the day after tomorrow. In order to be able to watch TV on the family and gossip about it, I have to re-do the old business (after the work, the black power gave up 8 years, it is only a spare time to repair the white electricity), find out the dusty multimeter, turn it out and try it. Fortunately, I found a soldering iron core.
. TV model: Changhong CHD28600, press the power switch indicator does not light, remove the TV, first measure the output resistance of each group of switching power supply, and find that the resistance of 7v to ground is 0. Online measurement VD832 (RU4) forward and reverse The resistance is 0, and the soldering is measured again to confirm that the short circuit has been broken. This diode is a 7V rectifier, which generates 5V and 3.3v through the regulator.
![3.png]()
The accessories have been given away, this can be difficult for me, suddenly a flash of light, find out the power of the abandoned computer at home, remove a SBL2040CT (Schottky rectifier diode withstand voltage 40v current 20A), only use one of the diodes On the machine, again measuring the 7V output to the ground resistance is basically normal, no matter what else, start the experiment, hehe! After the boot, after half an hour of testing, the temperature rises normally and the upper back cover is completed.
![1.png]()
![0.jpg]()
![5.jpg]()
![00.png]()
Surge Protection Device SPD
Product Description
SPD Surge Protective Device,Lightning Surge Protector
Surge Protection Device (SPD)
It is a device used to limiting instant surge voltage and discharge surge current, it at least including a non-linear component.
Surge protective Device Model Selection
With the impact of international information flow, the rapid development of microelectronic science and technology, communication, computer and automatic control technology, make the building start to go for high quality, high functional area, formed a new building style-intelligent building. As inside the intelligent building there are lot of information system, <<Building lightning protection design norm>> GB50057-94(2002 vision)(hereafter brief as <<lightning protection norm>>) put forward the relative requirement to install the surge protective device, to ensure the information system safely and stable running.
SPD essentially is a equipotential connection material, its model selection is according to the different lightning protection area, different lightning electromagnetic pulse critical and different equipotential connection position, decide which kind of SPD used in the area, to achieve the equipotential connection with the common earth electrode. Our statement will based on SPD's maximum discharge current Imax, continuous operating voltage Uc, protection voltage Up, alarm mode etc.
As per << Lightning Protection Norm>> item 6.4.4 stipulation "SPD must can withstand the expected lightning current flow and should confirm to the additional two requirements: the maximum clamp voltage during surge across, capable to extinguish the power frequency follow-on current after lightning current across." That is the value of SPD's max. clamp voltage add its induction voltage of two ends should be same with the system's basic insulation level and the equipment allowed max. surge voltage.
SPD for Power Supply System Series Selection Guide
The installation of SPD at each lightning protection zone, according to the standard of low voltage electrical appearance, make classification of electrical equipment in accordance with the over voltage category, its insulation withstand impulse voltage level can determine the selection of SPD. According to the standard of low voltage electrical appearance, make classification of electrical equipment in accordance with the over voltage category as signal level, loading level, distribution and control level, power supply level. Its insulation withstand impulse voltage level are:1500V,2500V,4000V,6000V. As per to the protected equipment installation position different and the different lightning current of different lightning protection zone, to determine the installation position of SPD for power supply and the break-over capacity.
The installation distance between each level SPD should not more than 10m, the distance between SPD and protected equipment should as short as possible, not more than 10m. If due to limitation of installation position, can't guarantee the installation distance, then need to install decoupling component between each level SPD, make the after class SPD can be protected by the prior class SPD. In the low voltage power supply system, connecting an inductor can achieve the decoupling purpose.
SPD for power supply system specification selection principle
Max. continuous operating voltage: bigger than protected equipment, the system's max. continuous operating voltage.
TT System: Uc≥1.55Uo (Uo is low voltage system to null line voltage)
TN System: Uc≥1.15Uo
IT System: Uc≥1.15Uo(Uo is low voltage system to line voltage)
Voltage Protection Level: less than the insulation withstand impulse voltage of protected equipment
Rated discharge current: determined as per to the lightning situation of the position installed and lightning protection zone.
SP1 Series
Normal Working Conditions
-Altitude not exceed 2000m
-Ambient air temperature:
Normal range: -5ºC~+40ºC
Extend range: -40ºC~+80ºC
-Relative Humidity: 30% - 90% under indoor temperature condition
- At the place without obviously shaking and shock vibration
- Non-explosion danger medium, non-corrosion gas and dust ( including conductive dust)
Classification
-As per Nominal Discharge Current:
5,10,20,30,40,60KA(8/20µs)
- As per Maximum continuous operating voltage:
275V,320V,385V,420V,440V,460V
- As per to poles
1P,1P+N,2P,3P,3P+N,4P
- As per auxiliary functions:
a. With remote signal output ( remote alarm function)
b. Without remote signal output
Selection Principle
- The continuous applied voltage on the two terminals of SPD should not more than the maximum continuous operating voltage Uc value;
- The voltage protection level Up of SPD should less than the maximum impulse withstand voltage of the protected equipment;
- As per to the different earthing system and protection mode to select the specification accordingly;
Product Features
1, built-in over-current overheating, temperature control circuit technology.
2, the module design, easy installation, online replacement.
3, low leakage current, fast response time, low residual voltage.
4, alarm indication device, green (normal) v red (fault).
Model/Technical Parameters
|
WR-B60
|
WR-B80
|
WR-B100
|
WR-B120
|
WR-B150
|
Rated Operating Voltage Un (V ~)
|
220V 380V
|
220V 380V
|
220V 380V
|
220V 380V
|
220V 380V
|
Maximum Continuous Operating Voltage Uc (V ~) kV
|
385V 420V
|
385V 420V
|
385V 420V
|
385V 420V
|
385V 420V
|
Voltage Protection Level Up (V ~) kV
|
≤1.8≤2.2
|
≤2.4≤2.5
|
≤2.5≤3.2
|
≤3.4≤3.7
|
≤4.0≤4.5
|
Maximum Discharge
Current Imax(8/μ20μs)kA
|
60
|
80
|
100
|
120
|
150
|
Nominal Discharge
Current In(8/μ20μs)kA
|
30
|
40
|
60
|
80
|
100
|
Response Time
|
<25
|
<100
|
L/N(mm²)The Cross Section Of L/N Line
|
16,25
|
16,25
|
16,25
|
16,25
|
25,35
|
PE (mm²)The Cross Section Of PE Line
|
16,25
|
25,35
|
25,35
|
25,35
|
35
|
Fuse or Switch (A)
|
63A
|
63A
|
63A,100A
|
63A,100A
|
63A,125A
|
The Line Section of Communication and Alarm (mm²)
|
≥ 1.5
|
Operating
Environment-C
|
(-40ºC~-+85ºC)
|
Relative humidity 25 ºC
|
≤95%
|
installation
|
Standard Rail35mm
|
Material of Outer Covering
|
Fiber Glass Reinforced Plastic
|
Surge Protector SPD,Surge Protection Device SPD,SPD
Wenzhou Korlen Electric Appliances Co., Ltd. , https://www.korlen-electric.com