Stone wear test machine test requirements and methods - Database & Sql Blog Articles

Test - lowercase jpg
Kaixin micro test
Test probe P100-M3

Stone wear tester test requirements and methods


Test requirements:

There are four samples in each group. length. Width size is

50m

m

±

0.5mm

, thickness is

15mm

-55mm

, the edge of the sample to be worn should be rounded to a radius of approximately

0.8mm

radian.

When testing, the test piece should be placed at a temperature

105

°C±

2

The test was carried out after cooling to room temperature in a desiccant in a thermostatic dry oven at °C.

experiment method:

1

The quality of the drying test is accurate to

0.02g

,

Then put it into the wear test machine to match

GB/T2479-1996

Standard requirement granularity is

0.25mm

White fused alumina is used as an abrasive and ground on a grinding disc

225

After the transfer, remove the sample and brush the dust, saying that the quality is accurate to

0.02g

.

2

Put the sample in the water

1h

After taking out, dry the surface with a damp cloth and weigh it. press

GB/T 9966.3-2001

The provisions calculate the bulk density. Since the humidity will affect the grinding effect, for example, the sample has a higher grinding rate when the humidity is higher, it is recommended that the test be in relative humidity (

30-40

)

%

In between.

3,

Clean the surface after the test is completed

,

Covered dust cover

.

Zinc Aluminum

Zinc aluminum alloy wire, zinc is the matrix, through different aluminum content to meet the needs of different customers, and the use of advanced production technology, strict quality control, surface and inner quality is good and stable, with good mechanical properties. Using in film capacitor surface spray

Zinc Aluminum Alloy Wire,Blasting Materials,Anti-Corrosion Spraying Material,Ductile Iron Pipe